When
the Newbury Hall was shifted across the road next to the Newbury School,
it required a new effluent system. To avoid using too much land for
effluent disposal, I designed a timer controlled LPED dosing system
which held the peak flow in a 'Uniclear' 25,000 litre septic tank
fitted with an OSI pump vault which slowly dosed the filtered effluent
into a 100 square metre disposal area at a rate the ground could absorb
and treat.
|

Newbury
Hall before relocation

Full
carpark

septic
tank at left rear of hall. Disposal in strip right hand side of
photo.
|

Newbury
Hall being relocated
Photo:
Graeme Brown, Manawatu Evening Standard

Looking
toward school effluent between carpark and fence.
|
|